3. Place the mouse cursor on a softkey and using the right-hand mouse key call the context
menu "Define access level", in order to define a new access level for this softkey.
– The displayed access level is the default setting.
– A softkey is practically made invisible with "Always hide".
– You can reset the additionally allocated access level using "Original setting". This
4. In order to accept changes, return to the "Start-up" operating area and there, press the
"Close customizing" softkey. This means that you exit the "Customize the softkey access
levels active" mode.
If you acknowledge the following query with "OK", then the changes are accepted and
become effective once the system has rebooted.
5. If the changes to a softkey are not to be applied, select the line in the "Adapt softkey access
levels" window and press the "Original setting" softkey. The identifier "Original setting" is
entered in the "New access level" column. After the end of the softkey adaptation and
system restart, the original setting of the softkey is restored and the line entry in the "Adapt
softkey access levels" window is deleted.
Example
The following access levels were changed:
Softkey
SISuMainScreenMenuHu::0::3
SIMaJogMillMenuHU::jogHuMore::6
SISuPaUserDataMenu::::4
Once selected, the identifier and position of the softkey are transferred to the "Softkey" column.
Result
When the changes have been accepted, a configuration file with the name
"slsoftkeyaccess.xml" is created and saved in the file system under the following path: ../user/
sinumerik/hmi/cfg. Files can also be saved on the /oem path; these files are evaluated when
the system boots. The following priority applies: oem < user.
Note
Editing the file "slsoftkeyaccess.xml"
In order to avoid errors in the xml syntax and for the softkey identifier the "slsoftkeyaccess.xml"
file may only be edited via the operating software as described above, and not directly in the
file system under "System data". It is possible that the complete file or individual entries for
softkeys can no longer be interpreted.
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
selection is only listed after an individual access level was set.