Operation Mode - ABB ACS560 Quick Installation And Start-Up Manual

General purpose drives standard control program
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

Index
Name
Zero[0]
Motor speed used[1]
Output frequency[3]
Motorcurrent[4]
Motor current% of
motor nominal[5]
Motor torque[6]
13.13
AO1 forced value
13.15
AO1 unit selection
13.16
AO1 filter time
13.17
AO1 source Min
13.18
AO1 source Max
13.19
AO1 out at AO1 src min
13.20
AO1 out at AO1 src Max
13.21
AO2 actual value
13.22
AO2 source
13.23
AO2 forced value
13.26
AO2 filter time
13.27
AO2 source min
13.28
AO2 source Max
13.29
AO2 out at AO2 src min
13.30
AO2 out at AO2 src Max
13.91
AO1 data storage
13.92
AO2 data storage

19 Operation mode

19.01
Actual operation mode
Range/List
DC voltage[7]
Abs motor speed
used[26]
Output power[8]
Abs motor
speed%[27]
Freq ref used [14]
Abs output fre-
quency[28]
Process PID out[16]
Abs motor
torque[30]
Temp sensor 1 excit-
Abs output
ation[20]
power[31]
Temp sensor 2 excit-
Abs motor shaft
ation[21]
power[32]
0.000...22.000
V[2], mA[10]
0.000 ... 30.000
-32768.0 ... 32767.0
-32768.0 ... 32767.0
0.000 ... 22.000
0.000 ... 22.000
0.000 ... 22.000
See parameter 13.12
AO1 source
0.000 ... 22.000
0.000 ... 30.000
-32768.0 ... 32767.0
-32768.0 ... 32767.0
0.000 ... 22.000
0.000 ... 22.000
-327.68 ... 327.67
-327.68 ... 327.67
1, 2, 10, 20
Parameter listing 59
Unit
Default
AO1 data stor-
age[37]
AO2 data stor-
age[38]
Other...
mA
0.000
-
mA[10]
s
0.100
-
0.0
-
50.0
mA
0.000
mA
20.000
mA
0.000
-
Motor current[4]
mA
0.000
s
0.100
-
0.0
-
3.2
mA
4.000
mA
20.000
-
0.00
-
0.00
-
Scalar (Hz)[10]
EN
HI

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents