Huawei USG6000 Upgrade Manual page 89

Hide thumbs Also See for USG6000:
Table of Contents

Advertisement

HUAWEI USG6000&USG9500
Upgrade Guide
HRP_S<FW_B> system-view
HRP_S[FW_B] interface GigabitEthernet 1/0/3
HRP_S[FW_B-GigabitEthernet1/0/3] shutdown
HRP_S[FW_B-GigabitEthernet1/0/3] quit
HRP_S[FW_B] interface GigabitEthernet 1/0/1
HRP_S[FW_B-GigabitEthernet1/0/1] shutdown
HRP_S[FW_B-GigabitEthernet1/0/1] quit
HRP_S[FW_B] interface GigabitEthernet 1/0/7
HRP_S[FW_B-GigabitEthernet1/0/7] shutdown
HRP_M[FW_B-GigabitEthernet1/0/7] quit
HRP_M[FW_B] quit
Step 3 Set the system software for the next startup of FW_B.
HRP_M<FW_B> startup system-software xxxxx.bin
Info:System software for the next startup:hda1:/xxxxx.bin, start read file....
Succeeded in setting the software for booting system.
Step 4 Restart FW_B.
HRP_M<FW_B> reboot
Info: The system is now comparing the configuration, please wait.
Warning: The configuration has been modified, and it will be saved to the next s
tartup saved-configuration file hda1:/vrpcfg.zip. Continue? [Y/N]:y
Now saving the current configuration to the slot 0....
Save the configuration successfully.
Info: If want to reboot with saving diagnostic information, input 'N' and then e
xecute 'reboot save diagnostic-information'.
System will reboot! Continue?[Y/N]:y
Step 5 After FW_B is restarted and the LPU and SPU are restored, run the shutdown command to
disable the service and heartbeat interfaces of FW_A (active device). After the service and
heartbeat interfaces of FW_A are disabled, services are interrupted. To reduce the service
interruption duration, after interfaces of FW_A are disabled, run the undo shutdown
command to enable the heartbeat and service interfaces of FW_B immediately and switch
service traffic to FW_B for forwarding.
# Run the shutdown command to disable the service and heartbeat interfaces of FW_A. You
must disable the service interface first and then the heartbeat interface.
HRP_M<FW_A> system-view
HRP_M[FW_A] interface GigabitEthernet 1/0/3
HRP_M[FW_A-GigabitEthernet1/0/3] shutdown
HRP_M[FW_A-GigabitEthernet1/0/3] quit
HRP_M[FW_A] interface GigabitEthernet 1/0/1
HRP_M[FW_A-GigabitEthernet1/0/1] shutdown
HRP_M[FW_A-GigabitEthernet1/0/1] quit
HRP_M[FW_A] interface GigabitEthernet 1/0/7
HRP_M[FW_A-GigabitEthernet1/0/7] shutdown
HRP_M[FW_A-GigabitEthernet1/0/7] quit
HRP_M[FW_A] quit
# Run the undo shutdown command to enable the heartbeat and service interfaces of FW_B.
You must enable the heartbeat interface first and then the service interface.
HRP_M<FW_B> system-view
HRP_M[FW_B] interface GigabitEthernet 1/0/7
HRP_M[FW_B-GigabitEthernet1/0/7] undo shutdown
HRP_M[FW_B-GigabitEthernet1/0/7] quit
HRP_M[FW_B] interface GigabitEthernet 1/0/3
HRP_M[FW_B-GigabitEthernet1/0/3] undo shutdown
HRP_M[FW_B-GigabitEthernet1/0/3] quit
HRP_M[FW_B] interface GigabitEthernet 1/0/1
HRP_M[FW_B-GigabitEthernet1/0/1] undo shutdown
HRP_M[FW_B-GigabitEthernet1/0/1] quit
Step 6 Set the system software for the next startup of FW_A.
Issue 01 (2018-01-16)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1 USG6000
80

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Usg9500

Table of Contents