6.8.2.1. Connecting auxiliary power cables and space heater cables in WCU

Top cable entry
1. Route the cables through the cable transit into the terminal compartment
(Fig. 6-23: 1) of the WCU.
2. Connect the cables to the relevant terminals.
Bottom entry
1. Route the cables through the floor or the top of the WCU, up the cable duct (4
in Fig. 6-23) on the right side wall and then into the terminal compartment (3
in Fig. 6-23) of the WCU.
2. Connect the cable to the bottom of the relevant terminals, according to the
converter wiring diagram.
A

Figure 6-23 Cable routing in WCU800 (A) and WCU1400 (B) cabinets

1) Terminal compartment
2) WCU800 cable entry bottom
PRODUCT
ACS5000W
1
2
4
DOCUMENT KIND
User manual
B
3) WCU1400 cable entry bottom
4) Cable entry top (WCU800 and WCU1400)