5.5. Preparing the installation site
To ensure proper alignment and installation of the drive, prepare the floor as
follows:
–
The floor must be able to support the weight of the drive
(min. 1500 kg/m
–
The overall incline of the floor across 5 m must not exceed 5 mm.
1 mm
1 mm
Figure 5-1 Floor inclination
1) Tolerance from mean ground ± 1 mm
2) Surface or floor
The floor must be even.
–
Check the evenness and incline of the floor well in advance so that work for
improving the surface is completed before the installation of the drive.
–
Use a spirit level or flooring rule with a vial for checking.
Recommended length: 1 – 2 m.
–
If the surface cannot be improved, place shims or leveling plates under the
base frame at appropriate distances (every 1 m) for adjustment.
–
Leveling plates of the following size are recommended: 10 mm x 10 mm
–
Drill the fixing holes before moving the drive to the final location.
PRODUCT
ACS5000W
2
).
1
1
5 m
DOCUMENT KIND
User manual
3
3) Tolerance for incline: 5 mm incline on 5 m
length
DOCUMENT ID.
3BHS799208 E01
MECHANICAL INSTALLATION
2
5 mm
REV.
LANG.
PAGE
F
en
69/178