Motorola APEX1000 Installation And Operation Manual page 172

All-purpose edge qam
Table of Contents

Advertisement

Item
Smoothing Period (ms)
Buffer Depth (ms)
Index
Enable
Input IF
Input UDP
Multicast IP
Source IP
Manual Routing • Manual Routing TS Redundancy
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
Data Stream Identification window field definitions
Definition
Amount of time in milliseconds that the GigE will attempt to smooth out
the received data stream. This value is used along with the Buffer Depth to
best smooth out data streams.
The GigE will use the total smoothing period and divide by the number of
packets received during this time to determine an equal spaced out play
out rate.
Range: 250 – 650ms (must be less than or equal to Buffer Depth)
Buffer Depth in milliseconds for data-only input streams.
This is the amount of time that data only input streams are buffered by the
GigE processor. These streams are then played out using the Smoothing
Period to attempt to transmit packets to the proper output at an equally
spaced out rate. This will help to remove network jitter and remove bursts
from the input stream.
Range: 250 – 650ms (must be greater than or equal to Smoothing Period)
Active Streams / Available Streams
Index of table entry (1 – 768).
Enabled entry indicator. Set this to enable an input stream to identify it as a
data-only input stream.
Specifies the GigE port as the input interface.
Specifies the GigE input UDP port.
Range: 0 – 65535
The Gigabit Ethernet Receive Multicast IP Address.
The Gigabit Ethernet IGMP v3 Source IP Address.
Warning! Only list streams without PCR packets in this table. Do NOT
add video/audio input streams to this table.