To configure the RTSP controller interface:
1. Configure the Streaming Zone.
Note: This value must match the value previously configured in the Session
Controller.
2. Configure the APEX Device Name.
3. Configure the Manager Port with the TCP Port on which the communication with the
controller will occur (if not using the default TCP Port – 7100). (If in MHA mode,
configure the MHA manager port and address domain.)
4. Configure the Manager IP Address with the IP address of the session controller.
5. Configure the Hold Time. This is the amount of time (in seconds) that the APEX
waits for communication from the session controller before considering the
connection as having been dropped.
Note: Motorola recommends setting the Hold Time to 30 s.
6. Click Apply to apply these changes to the APEX1000. (A VREP session will be
established with the controller.)
7. Click Refresh to update the Communication Status, and confirm that the controller is
both Discovered and Connected.
Confirming RTSP Configuration
Use the following windows to verify RTSP operation on the APEX1000:
SDV > RTSP Controller Configuration — Provides controller discovery information.
For more information, see
SDV > RTSP Status — Provides route information, including source IP, UDP port,
program numbers, and bandwidth used.
For more information, see
SDV > RTSP QAM Status — Provides status on each QAM, including the number
of active sessions and the bandwidth allocated to them.
For more information, see
Configuring for Switched Digital Video • Step by Step Instructions
APEX1000 All-Purpose Edge QAM Software Version 2.4.x • Installation and Operation Manual
573408-001-a
RTSP Controller
Configuration.
RTSP
Status.
RTSP QAM
Status.