Close the front cover and the maintenance cover (left).

Belt Cleaning Tank Flow Rate Adjustment

If the flow rate to the belt cleaning tank is not adjusted properly, the belt may not be cleaned properly resulting in
fabric stains, or drainage may be insufficient resulting in water overflows.
If you are using the included valve and hose, follow the steps below to adjust the flow rate.
If you are not using the valve and hose, check the factory equipment.
Required Items
*: You can perform adjustment even without a flow meter. If you do not have a flow meter, prepare a container with a capacity of
0.5 L.
A
Check that Lift Up is displayed in Belt Cleaning Tank on the Home screen on the control panel.
When Set Down is displayed, touch the display area and lower the cleaning tank.
B
From the Maintenance screen on the control panel, touch Maintenance - Cleaning the Cleaning Tank, in
that order.
C
Check the on-screen message, and then touch Start.
Supply of water to the cleaning tank begins, and the pressure on the supply valve is released.
D
Hold the handles at the front and pull out the belt cleaning unit.
A
Handles
Maintenance
*
Nut, flow meter
, bucket, protective gloves, eye protection, and protective
clothing