ESSI Programming Model
7.5.3

ESSI Status Register (SSISR)

The SSISR is a read-only status register by which the DSP reads the ESSI status and serial
input flags.
23
22
21
11
10
9
—Reserved bit; read as 0; write to 0 0 for future compatibility.
Table 7-5. ESSI Status Register (SSISR) Bit Definitions
Bit Number
Bit Name
23–8
7
RDF
6
TDE
5
ROE
4
TUE
7-28
20
19
18
8
7
6
RDF
TDE
(ESSI0 X:$FFFFB7, ESSI1 X:$FFFFA7)
Figure 7-11. ESSI Status Register (SSISR)
Reset Value
0
Reserved. Write to 0 for future compatibility.
0
Receive Data Register Full
Set when the contents of the receive shift register transfer to the receive
data register. RDF is cleared when the DSP reads the receive data
register. If RIE is set, a DSP receive data interrupt request is issued when
RDF is set.
0
Transmit Data Register Empty
Set when the contents of the transmit data register of every enabled
transmitter are transferred to the transmit shift register. It is also set for a
TSR disabled time slot period in Network mode (as if data were being
transmitted after the TSR has been written). When TDE is set, TDE data is
written to all the TX registers of the enabled transmitters or to the TSR.
The TDE bit is cleared when the DSP writes to all the transmit data
registers of the enabled transmitters, or when the DSP writes to the TSR
to disable transmission of the next time slot. If the TIE bit is set, a DSP
transmit data interrupt request is issued when TDE is set.
0
Receiver Overrun Error Flag
Set when the serial receive shift register is filled and ready to transfer to
the receive data register (RX) but RX is already full (that is, the RDF bit is
set). If the REIE bit is set, a DSP receiver overrun error interrupt request is
issued when the ROE bit is set. The programmer clears ROE by reading
the SSISR with the ROE bit set and then reading the RX.
0
Transmitter Underrun Error Flag
TUE is set when at least one of the enabled serial transmit shift registers
is empty (that is, there is no new data to be transmitted) and a transmit
time slot occurs. When a transmit underrun error occurs, the previous data
(which is still present in the TX registers not written) is retransmitted. In
Normal mode, there is only one transmit time slot per frame. In Network
mode, there can be up to 32 transmit time slots per frame. If the TEIE bit is
set, a DSP transmit underrun error interrupt request is issued when the
TUE bit is set. The programmer can also clear TUE by first reading the
SSISR with the TUE bit set, then writing to all the enabled transmit data
registers or to the TSR.
DSP56303 User's Manual
17
16
15
5
4
3
ROE
TUE
RFS
Description
14
13
12
2
1
0
TFS
IF1
IF0