8.
Removing the Manual Feed Tray
Paper Sensor
1) Remove the mounting screw [1], and de-
tach the solenoid cover [2].
2) Remove the mounting screw [3], and de-
tach the solenoid [4] together with the up-
per plate.
3) Remove the screw [5], and detach the con-
nector cover [6]; then, disconnect the con-
nector [7].
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 7 PICK-UP/FEEDING SYSTEM
[1]
[2]
Figure 7-A813
[3]
[4]
Figure 7-A814
[6]
[7]
Figure 7-A815
[5]
7-49