Ac Power Is Absent - Canon GP605 Service Manual

Table of Contents

Advertisement

CHAPTER 13 TROUBLESHOOTING
62

AC power is absent.

Cause
Step
Power plug
Main power
supply
Leakage breaker
Power cord,
Line filter (LF1)
Power switch
(SW1)
Wiring
13-102
COPYRIGHT © 1999 CANON INC.
1
Is the power plug connected to the power
outlet securely?
2
Is the rated AC voltage present at the
power outlet?
3
Remove the rear cover. Has the leakage
breaker mounted on the power cord
mount turned on (i.e., the switch is at
4
Replace the power or and the line filter
(LF1). Is there AC power?
5
Connect the meter probes to both
terminals of the power switch (SW1). Is
the reading 0Ω when the switch is turned
on and ∞ Ω when it is turned off?
Checks
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Yes/No
Action
NO
Connect the power
plug securely.
NO
Inform the user that the
problem is not of the
copier's.
NO
Remove the cause that
turned on the leakage
).
breaker, and shift its
switch to |.
YES
End.
NO
Check the AC power
line for wiring and the
connectors for poor
contact.
NO
Replace the power
switch.
YES
Check the AC power
line for wiring and the
connector for poor
contact.