CHAPTER 11 INSTALLATION
8) If IC6 [11] is mounted on the PCB of the
controller, shift SW2-7 of the DIP switch
[12] to ON; otherwise, shift the bit to
OFF.
Note 1: If the IC6 [11] is not mounted, you
need not mount one.
Note 2: If the ROM (IC6) [15] is mounted or if
you are replacing it, be sure to shift
SW2-7 of the DIP switch [12] to ON.
9) Set the bits of the DIP switch (SW3) [13]
on the PCB of the controller as shown in
Table 11-501.
Switch
Setting
See
SW3-1
SW3-2
right.
OFF
SW3-3
ON
SW3-4
OFF
ON
SW3-5
OFF
SW3-6
11-30
COPYRIGHT © 1999 CANON INC.
SW3-1 SW3-2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Keep it to OFF at all times.
Sets the line to push pulse.
Sets the line to dial pulse.
Sets the dial pulse speed to 20PPS.
Sets the dial pulse speed to 10PPS.
Not used.
Table 11-501
LED1 LED2 LED3
LED5
LED6
LED4
IC6
SW1
Figure 11-508
[13]
LED1 LED2 LED3
LED5
LED6
LED4
IC6
SW1
Figure 11-509
Description
Description
Set the modem signal transmission level to -16 dBm.
Set the modem signal transmission level to -14 dBm.
Set the modem signal transmission level to -12 dBm.
Set the modem signal transmission level to -10 dBm.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[12]
2
6
BAT1
1
1
1
SW2
SW3
SW4
2
CN4
[11]
CN3
CN2
2
6
BAT1
1
1
1
SW2
SW3
SW4
2
CN4
CN3
CN2