CHAPTER 13 TROUBLESHOOTING
4) Fit the potential sensor tester electrode (FY9-3041) to the potential sensor.
Caution:
When fitting the tester electrode to the potential sensor, take care so that the magnet of the
electrode will not come into contact with the potential sensor cover.
5) Connect the cable of the potential sensor tester electrode to the support metal plate (GND) of
the potential measurement PCB.
Caution:
Be sure not to bring the clip into contact with the sensor cover by keeping it sufficiently away
from the window of the sensor.
Potential sensor support plate
13-16
COPYRIGHT © 1999 CANON INC.
Potential sensor
tester electrode
Potential sensor
Figure 13-C201
Cable
Figure 13-C202
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)