Problem
Event ID280 (spsdsm) is generated
in the system event log.
Event ID10 (WinMgmt/WMI) is
generated in the application event
log.
Release 6.0
Cause and Solution
Check if the configuration of connections between the
servers and the disk array unit has been changed due to an
event such as replacement of an HBA or reconnection of an
FC cable. Delete the old configuration information by
running spsadmin/deletemissing.
This event is generated due to the specification of the SPS,
and is not indication of abnormality. This does not affect the
operation of the system.
Source: WinMgmt (Case of Windows Server 2003)
WMI (Case of Windows Server 2008)
EventID: 10
Type: Error
Description:
Event filter with query "select * from
SPN_EVENTENTRY" could not be (re)activated in
namespace "//./root/WMI" because of error 0x80041010.
Events may not be delivered through this filter until the
problem is corrected.
Or,
Event filter with query "select * from
NEC_MAM_EVENTENTRY" could not be (re)activated in
namespace "//./root/WMI" because of error 0x80041010.
Events may not be delivered through this filter until the
problem is corrected.
293
Chapter 10 Troubleshooting