NEC Storage M100 Series User Manual page 384

Disk array unit
Hide thumbs Also See for Storage M100 Series:
Table of Contents

Advertisement

User Guide
Display may vary slightly among different operating systems.
2. Check the PathManager status
Check /proc/scsi/sps/ddX, where X is a, b, c, ... (number of logical disks assigned to server).
The path-info: line exists only for multiplexed sections of each device, and if NML appears in all of
the status columns of device-info:, paths are normally multiplexed.
If nothing is shown, none of the access paths recognized the logical disks of the disk array
unit assigned to the application server. Check the connection between the application
server and the disk array unit, the Access Control settings, host bus adapter driver
settings, etc.
Display example: When two logical disks are assigned to a server, with two access paths per logical
disk.
# cat /proc/scsi/sps/dda
device:/dev/dda
disk-info:NEC,DISK ARRAY,xxxxxxxxxxxxxxxx,xxxxx
device-info:Host:scsi:2 Channel:0 Id:0 Lun:0 Watch:Enable Status:NML
LoadBalance:D2
path-info:0 Host:scsi:0 Channel:0 Id:0 Lun:0 Priority:1 Status:ACT
path-info:1 Host:scsi:1 Channel:0 Id:0 Lun:0 Priority:2 Status:HOT
#
3. Check the path patrol daemon
Confirm that the path patrol daemon is running.
When the path patrol daemon is started, the following message is displayed.
# /etc/rc.d/init.d/dd_daemon status
dd_daemon (pid XXX) is running ...
#
Release 6.0
Appendix E How to Set/Check Application Server (Linux) (FC/SAS)
384