Cabling - Toshiba strata CT Installation & Maintenance Manual

Digital business telephone system
Hide thumbs Also See for strata CT:
Table of Contents

Advertisement

Cabling

Cable Installation
H
C
Figure 10-3
Strata CT I&M Manual October 2000
To meet Part 15 of EMC Rules, ISDN PRI equipment must be connected using CAT5,
Shielded Twisted-Pair (STP) cabling between the NTE and the RPTU. CAT5 STP protects
against cross talk, Radio Frequency Interference (RFI), and/or Electro Magnetic Interference
(EMI). STP protects ISDN signal data while being transmitted through the cable and keeps
the cable itself from emitting EMI and RFI.
Important!
To avoid ground loops, connect only the RPTU end of the shielded cable to
earth. The NTE earth should not be connected to the cable shield.
A detailed pinout diagram for the RJ45 jacks and the modular cords/adaptors is shown in
Figure 10-3
on
Page
10-7.
Toshiba will ship a 5 metre shielded patch cord terminated with BS EN28877 connectors with
each RPTUIF.
The RPTU PCB is shipped with a Toshiba RPRI cable kit for connection of the RPTU to a
CSU. Install the kit as shown in
ISDN PRI
Network
Jack
RJ45
2752 CT I&M
RJ45 Contact No.
1
2
3
4
5
6
7
8
Detailed Pinouts for ISDN PRI Cabling
Figure
10-4.
D
A
TE
RX
RX
Shield
TX
TX
Shield
Not Used
Not Used
ISDN Interfaces
RPTU
E
10-7