Strata CT Installation

PCB Installation Considerations

The Base Cabinet has ten slots. The first two slots, labelled "B101" and "B102" are reserved
for the common control unit and future feature upgrades. The next eight slots (labelled
"S101" ~"S108") are universal and capable of hosting any of the station, line, and option
interface PCBs compatible with the Strata CT systems.
The Expansion Cabinets have ten universal slots, labelled "S_01," "S_02," etc., where the
blank space of the label represents the number of the Expansion Cabinet. Like the universal
slots in the Base Cabinet, these universal slots are capable of hosting any of the station, line,
and option interface PCBs (except RSIU which can only be installed in slot S101 of the Base
Cabinet).
Cabinets are numbered from 1 to 5. The Base Cabinet is numbered 1; the first Expansion
Cabinet, number 2; the second Expansion Cabinet, number 3, etc. See the Strata CT
Configuration and Universal Slot PCB section for details regarding PCB installation.

PCB Option Considerations

Strata CT PCBs can be configured for a variety of hardware and software options. Hardware
options are defined as either internal (generally related to optional PCB subassemblies) or
external (related to connection of peripheral equipment such as background music, voice
mail, etc.).
H
Hardware Options
Some PCBs must be configured for hardware options prior to installation of the PCB in the
cabinet. Configuration instructions for internal hardware options are provided in the
individual PCB installation procedures in this chapter and in
PCBs. Configuration instructions for external hardware options are provided in
Peripheral
C
Software Options
PCBs are configured for software options through programming, following the installation
instructions of the PCBs. A programming overview for each PCB is provided in the
individual PCB installation procedures in this chapter. Refer to the Strata CT Programming
Manual for detailed programming instructions.
2-36
Installation.
Chapter 3 – Universal Slot
Chapter 6 –
Strata CT I&M Manual October 2000