Rsis, Rmds Piggy-Back Installation; Rsiu Installation - Toshiba strata CT Installation & Maintenance Manual

Digital business telephone system
Hide thumbs Also See for strata CT:
Table of Contents

Advertisement

Universal Slot PCBs
The communication parameters for an RSIU, RSIS SMDR port is:
N
N
N
Only one RSIU can be installed per Strata CT system. When the RSIU PCB is installed, the
RSSU, PIOU2, PIOUS2, IMDU modem, and PEPU PCBs can still be installed with all of
their respective paging, modem, and RS-232 port functions available; however, five RS-232/
modem ports can be installed in one Strata CT system.
When installed together in the same Strata CT system, the RSIU, PIOU2, PIOUS2, RSSU
port functions are identified and enabled (turned On/Off) in system programming. If the same
function is programmed for an RSIU port and a PIOU2, PIOUS2, RSSU port, only the RSIU
port will function.

RSIS, RMDS Piggy-Back Installation

1.
H
2.

RSIU Installation

C
1.
2.
3.
All information provided in the
RSIU in an existing system. Hence, most PCBs must be moved to the next highest slot.
3-30
Data word bits = 8
Parity = none
Stop bits = 1
Install all RSIS and RMDS PCBs on the RSIU PCB before installing the RSIU into the
Strata CT. Each RSIS or RMDS piggy-back PCB is installed on the RSIU PCB as
shown in
Figure 3-14
on
Up to three RSIS PCBs can be installed on the RSIU PCB; only one RMDS PCB can be
installed on the RSIU. The function and bit-per-second (bps) data rate of each RSIS and
RMDS circuit port is set in Program 76 as described in the Programming Part that
follows.
After installing all RSIS, RMDS PCBs, install the RSIU into the Strata CT per the
following instructions.
The RSIU must be installed only in slot 11 of the base cabinet (see
the RSIU PCB).
A PDKU or PEKU PCB must be installed in slot 12 of the base cabinet to support the
programming telephone.
The first 8-station ports (000-007) appear on the PDKU or PEKU as installed in slot 12.
The programming telephone will then be on the 6th circuit (port 005; or, 013 until
Program 03 Code 49 is set for slot 11) of the PDKU in slot 12.
The function and bit-per-second (bps) data rate of the RSIU or RMDS, RS-232 circuit
port is set in Program 76 as described in the Strata CT Programming Manual.
Page
3-31.
"RSIU Installation" on Page 3-30
Figure 3-14
applies to installing an
Strata CT I&M Manual October 2000