Chapter 3
Device Management
Parameter
Index
Variable
Rising Thr
Falling Thr
Value
Type
Interval
Startup Alarm
Rising Event
100
Description
Synopsis:   1 to 65535
Default:   1
The index of this RMON Alarm record.
Synopsis:   SNMP Object Identifier - up to 39 characters
The SNMP object identifier (OID) of the particular variable to
be sampled. Only variables that resolve to an ASN.1 primitive
type INTEGER (INTEGER, Integer32,Counter32, Counter64,
Gauge, or TimeTicks) may be sampled. A list of objects can
be printed using shell command 'rmon'. The OID format:
objectName.index1.index2... where index format depends on
index object type.
Synopsis:   -2147483647 to 2147483647
Default:   0
A threshold for the sampled variable. When the current sampled
variable value is greater than or equal to this threshold, and the
value at the last sampling interval was less than this threshold,
a single event will be generated. A single event will also be
generated if the first sample after this record is created is greater
than or equal to this threshold and the associated startup alarm
ils equal to 'rising'.After rising alarm is generated, another such
event will not be generated until the sampled value falls below
this threshold and reaches the value of FallingThreshold.
Synopsis:   -2147483647 to 2147483647
Default:   0
A threshold for the sampled variable. When the current sampled
variable value is less than or equal to this threshold, and the value
at the last sampling interval was greater than this threshold,
a single event will be generated. A single event will also be
generated if the first sample after this record is created is less
than or equal to this threshold and the associated startup alarm
ils equal to 'falling'.After falling alarm is generated, another such
event will not be generated until the sampled value rises above
this threshold and reaches the value of RisingThreshold.
Synopsis:   -2147483647 to 2147483647
The value of monitoring object during the last sampling period.
The presentation of value depends of sample type ('absolute' or
'delta').
Synopsis:   { absolute, delta }
Default:   delta
The method of sampling the selected variable and calculating the
value to be compared against the thresholds. The value of sample
type can be 'absolute' or 'delta'.
Synopsis:   0 to 2147483647
Default:   60
The number of seconds in over which the data is sampled and
compared with the rising and falling thresholds.
Synopsis:   { rising, falling, risingOrFalling }
Default:   risingOrFalling
The alarm that may be sent when this record is first created if
condition for raising alarm is met. The value of startup alarm can
be 'rising', 'falling' or 'risingOrFalling'.
Synopsis:   0 to 65535
Default:   0
RUGGEDCOM ROS
User Guide
Adding an RMON Alarm