Siemens RUGGEDCOM ROS v4.3 User Manual page 91

Table of Contents

Advertisement

RUGGEDCOM ROS
User Guide
Figure 27: Port Rate Limiting Table
2.
Select an Ethernet port. The Port Rate Limiting form appears.
5
Figure 28: Port Rate Limiting Form
1. Port Box    2. Ingress Limit Box    3. Ingress Frames List    4. Egress Limit Box    5. Apply Button    6. Reload Button
3.
Configure the following parameter(s) as required:
Parameter
Port
Ingress Limit
Ingress Frames
Configuring Port Rate Limiting
Description
Synopsis:   1 to maximum port number
Default:   1
The port number as seen on the front plate silkscreen of the
switch.
Synopsis:   62 to 256000 Kbps or { Disabled }
Default:   1000 Kbps
The rate after which received frames (of the type described by the
ingress frames parameter) will be discarded by the switch.
Synopsis:   { Broadcast, Bcast&Mcast, Bcast&Mcast&FloodUcast,
Bcast&FloodUcast, FloodUcast, All }
Default:   Broadcast
This parameter specifies the types of frames to be rate-limited on
this port. It applies only to received frames:
• Broadcast - only broadcast frames
Chapter 3
Device Management
1
2
3
4
6
75

Advertisement

Table of Contents
loading

Table of Contents