Siemens RUGGEDCOM ROS v4.3 User Manual page 53

Table of Contents

Advertisement

RUGGEDCOM ROS
User Guide
Command
clearlogs
clrcblstats [ all |
clrstpstats
cls
dir
exit
factory
flashfiles { info filename
defrag }
flashleds
timeout
fpgacmd
help
command
ipconfig
loaddflts
login
logout
logs
ping
{
address
}
timeout
Available CLI Commands
Description
• port is a comma separated list of port numbers (e.g. 1,3-5,7)
Clears the system and crash logs.
Clears cable diagnostics statistics for one or more ports.
port
]
Optional and/or required parameters include:
• all clears statistics for all ports
• port is a comma separated list of port numbers (e.g. 1,3-5,7)
Clears all spanning tree statistics.
Clears the screen.
Prints the directory listing.
Terminates the session.
Enables factory mode, which includes several factory-level commands used for testing and
troubleshooting. Only available to admin users.
A set of diagnostic commands to display information about the Flash filesystem and to
|
defragment Flash memory.
Optional and/or required parameters include:
• info filename displays information about the specified file in the Flash file system
• defrag defragments files in the Flash file system
For more information about the flashfiles command, refer to
the Flash File System"
Flashes the LED indicators on the device for a specified number of seconds.
Optional and/or required parameters include:
• timeout is the number of seconds to flash the LED indicators. To stop the LEDs from
flashing, set the timeout period to 0 (zero).
Provides access to the FPGA management tool for troubleshooting time synchronization.
Displays a brief description of the specified command. If no command is specified, it displays
a list of all available commands, including a description for each.
Optional and/or required parameters include:
• command is the command name.
Displays the current IP address, subnet mask and default gateway. This command provides
the only way of determining these values when DHCP is used.
Loads the factory default configuration.
Logs in to the shell.
Logs out of the shell.
Displays syslog entries in CLI shell.
|
Sends an ICMP echo request to a remotely connected device. For each reply received, the
count
round trip time is displayed. Use this command to verify connectivity to the next connected
device. It is a useful tool for testing commissioned links. This command also includes the
ability to send a specific number of pings with a specified time for which to wait for a
response.
Optional and/or required parameters include:
CAUTION!
Misuse of the factory commands may corrupt the operational state of device
and/or may permanently damage the ability to recover the device without
manufacturer intervention.
.
Chapter 2
Using ROS
Section 2.8, "Managing
37

Advertisement

Table of Contents
loading

Table of Contents