Figure 143: Global LLDP Parameters Form
1. State Options    2. Tx Interval Box    3. Tx Hold Box    4. Reinit Delay Box    5. Tx Delay Box    6. Apply Button    7. Reload Button
2.
Configure the following parameter(s) as required:
Parameter
State
Tx Interval
Tx Hold
Reinit Delay
Tx Delay
Click Apply.
3.
Configuring LLDP Globally
Description
Synopsis:   { Disabled, Enabled }
Default:   Enabled
Enables LLDP protocol. Note that LLDP is enabled on a port when
LLDP is enabled globally and along with enabling per port setting
in Port LLDP Parameters menu.
Synopsis:   5 to 32768 s
Default:   30 s
The interval at which LLDP frames are transmitted on behalf of
this LLDP agent.
Synopsis:   2 to 10
Default:   4
The multiplier of the Tx Interval parameter that determines the
actual time-to-live (TTL) value used in a LLDPDU. The actual TTL
value can be expressed by the following formula:
TTL = MIN(65535, (Tx Interval * Tx Hold))
Synopsis:   1 to 10 s
Default:   2 s
The delay in seconds from when the value of Admin Status
parameter of a particular port becomes 'Disbled' until re-
initialization will be lattempted.
Synopsis:   1 to 8192 s
Default:   2 s
The delay in seconds between successive LLDP frame
transmissions initiated by value or status changed. The
recommended value is set by the following formula:
1 <= txDelay <= (0.25 * Tx Interval)