04 Fault History; Reference Select - ABB ACS150 series User Manual

0.37...4kw; 0.5...5 hp
Hide thumbs Also See for ACS150 series:
Table of Contents

Advertisement

Parameters in the Short parameter mode
No.
Name/Value
9905
MOTOR NOM VOLT
200 V E units/
230 U units:
100...300 V
400 V E units /
460 V U units:
230...690 V
9906
MOTOR NOM CURR
0.2...2.0 · I
2N
9907
MOTOR NOM FREQ
10.0...500.0 Hz

04 FAULT HISTORY

0401
LAST FAULT
11 REFERENCE
SELECT
1105
REF1 MAX
0.0...500.0 Hz
Description
Defines the nominal motor voltage. Must be equal to the value on the motor
rating plate. The drive cannot supply the motor with a voltage greater than
the input power voltage.
Note that the output voltage is not limited by the nominal motor voltage but
increased linearly up to the value of the input voltage
Output voltage
Input voltage
9905
WARNING! Never connect a motor to a drive which is connected to power
line with voltage level higher than the rated motor voltage.
Voltage.
Note: The stress on the motor insulations is always dependent on the drive
supply voltage. This also applies to the case where the motor voltage rating
is lower than the rating of the drive and the supply of the drive.
Defines the nominal motor current. Must be equal to the value on the motor
rating plate.
Current
Defines the nominal motor frequency, that is the frequency at which the
output voltage equals the motor nominal voltage:
Field weakening point = Nom. frequency · Supply voltage / Mot nom. voltage
Frequency
Fault history (read-only)
Fault code of the latest fault. See chapter
codes. 0 = fault history is clear (on panel display = NO RECORD).
Maximum reference
Defines the maximum value for external reference REF1. Corresponds to
maximum mA/(V) signal for analog input AI1.
REF (Hz)
1105
(MAX)
0
1301
Maximum value
Output frequency
9907
Fault tracing
on page
AI1 signal (%)
100%
(20 mA / 10 V)
Actual signals and parameters
81
Def
200 V
E units:
200 V
230 V
U units:
230 V
400 V
E units:
400 V
460 V
U units:
460 V
I
2N
E: 50 / U: 60
127
for the
-
E: 50.0 Hz /
U: 60.0 Hz