Parameters in the Long parameter mode
Index Name/Selection
4019
ACT1 MAXIMUM
-1000...1000%
4020
ACT2 MINIMUM
-1000...1000%
4021
ACT2 MAXIMUM
-1000...1000%
4022
SLEEP SELECTION
0 = NOT SEL
1 = DI1
2 = DI2
3 = DI3
4 = DI4
5 = DI5
7 = INTERNAL
-1 = DI1(INV)
-2 = DI2(INV)
-3 = DI3(INV)
-4 = DI4(INV)
-5 = DI5(INV)
Description
Defines the maximum value for the variable ACT1 if an analog input is
selected as a source for ACT1. See parameter
minimum
(4018
ACT1 MINIMUM) and maximum settings of ACT1 define how
the voltage/current signal received from the measuring device is converted to
a percentage value used by the process PID controller.
See parameter
4018
ACT1 MINIMUM.
Value in percent
See parameter
4018
ACT1 MINIMUM.
See parameter
4018
ACT1 MINIMUM.
See parameter
4019
ACT1 MAXIMUM.
See parameter
4019
ACT1 MAXIMUM.
Activates the sleep function and selects the source for the activation input.
No sleep function selected
The function is activated/deactivated through digital input DI1. 1 = activation,
0 = deactivation.
The internal sleep criteria set by parameters
4025
WAKE-UP DEV are not effective. The sleep start and stop delay
parameters
4024
PID SLEEP DELAY and
effective.
See selection 1 (DI1).
See selection 1 (DI1).
See selection 1 (DI1).
See selection 1 (DI1).
Activated and deactivated automatically as defined by parameters
SLEEP LEVEL and
4025
The function is activated/deactivated through inverted digital input DI1.
1 = deactivation, 0 = activation.
The internal sleep criteria set by parameters
4025
WAKE-UP DEV are not effective. The sleep start and stop delay
parameters
4024
PID SLEEP DELAY and
effective.
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
See selection DI1(INV).
4016
4023
PID SLEEP LEVEL and
4026
WAKE-UP DELAY are
WAKE-UP DEV.
4023
PID SLEEP LEVEL and
4026
WAKE-UP DELAY are
Def
100%
ACT1 INPUT. The
0%
100%
0 = NOT SEL
4023
PID
Actual signals and parameters