80

Parameters in the Short parameter mode

The following table describes the parameters that are visible in the Short parameter
mode. See section
mode. All parameters are presented in detail in section
parameter
Parameters in the Short parameter mode
No.
Name/Value

99 START-UP DATA

9902
APPLIC MACRO
1 = ABB STANDARD
2 = 3-WIRE
3 = ALTERNATE
4 = MOTOR POT
5 = HAND/AUTO
6 = PID CONTROL
31 = LOAD FD SET
0 = USER S1 LOAD
-1 = USER S1 SAVE
-2 = USER S2 LOAD
-3 = USER S2 SAVE
-4 = USER S3 LOAD
-5 = USER S3 SAVE
Actual signals and parameters
Parameter modes
mode, starting on page 86.
Description
Application macro. Definition of motor set-up data.
Selects the application macro or activates FlashDrop parameter values. See
chapter
Application macros
Standard macro for constant speed applications
3-wire macro for constant speed applications
Alternate macro for start forward and start reverse applications
Motor potentiometer macro for digital signal speed control applications
Hand/Auto macro to be used when two control devices are connected to the
drive:
- Device 1 communicates through the interface defined by external control
location EXT1.
- Device 2 communicates through the interface defined by external control
location EXT2.
EXT1 or EXT2 is active at a time. Switching between EXT1/2 through digital
input.
PID control. For applications in which the drive controls a process value. For
example, pressure control by the drive running the pressure boost pump.
Measured pressure and the pressure reference are connected to the drive.
FlashDrop parameter values as defined by the FlashDrop file.
FlashDrop is an optional device for fast copying of parameters to unpowered
drives. FlashDrop allows easy customisation of the parameter list, for
example, selected parameters can be hidden. For more information, see
MFDT-01 FlashDrop user's manual (3AFE68591074 [English]).
User 1 macro loaded into use. Before loading, check that the saved
parameter settings and the motor model are suitable for the application.
Save User 1 macro. Stores the current parameter settings and the motor
model.
User 2 macro loaded into use. Before loading, check that the saved
parameter settings and the motor model are suitable for the application.
Save User 2 macro. Stores the current parameter settings and the motor
model.
User 3 macro loaded into use. Before loading, check that the saved
parameter settings and the motor model are suitable for the application.
Save User 3 macro. Stores the current parameter settings and the motor
model.
on page
65
for how to select the parameter
on page 69.