Actual signals
No.
Name/Value
0142
REVOLUTION CNTR
0143
DRIVE ON TIME HI
0144
DRIVE ON TIME LO
0160
DI 1-5 STATUS
0161
PULSE INPUT FREQ
0162
RO STATUS

04 FAULT HISTORY

0401
LAST FAULT
0402
FAULT TIME 1
0403
FAULT TIME 2
0404
SPEED AT FLT
0405
FREQ AT FLT
0406
VOLTAGE AT FLT
0407
CURRENT AT FLT
0408
TORQUE AT FLT
0409
STATUS AT FLT
0412
PREVIOUS FAULT 1
0413
PREVIOUS FAULT 2
0414
DI 1-5 AT FLT
Description
Motor revolution counter (millions of revolutions). The counter can be reset by pressing
the UP and DOWN keys simultaneously when the control panel is in the Parameter
mode.
Drive control board power-on time in days. Counter cannot be reset.
Drive control board power-on time in 2 second ticks (30 ticks = 60 seconds). Counter
cannot be reset.
Status of digital inputs. Example: 10000 = DI1 is on, DI2...DI5 are off.
Value of frequency input in Hz
Status of relay output. 1 = RO is energized, 0 = RO is de-energized.
Fault history (read-only)
Fault code of the latest fault. See chapter
fault history is clear (on panel display = NO RECORD).
Day on which the latest fault occurred.
Format: The number of days elapsed after power-on.
Time at which the latest fault occurred.
Format: Time elapsed after power-on in 2 second ticks (minus the whole days stated by
signal
0402
FAULT TIME 1). 30 ticks = 60 seconds.
For example, value 514 equals 17 minutes and 8 seconds (= 514/30).
Motor speed in rpm at the time the latest fault occurred
Frequency in Hz at the time the latest fault occurred
Intemediate circuit voltage in V DC at the time the latest fault occurred
Motor current in A at the time the latest fault occurred
Motor torque in percent of the motor nominal torque at the time the latest fault occurred
Drive status in hexadecimal format at the time the latest fault occurred
Fault code of the 2nd latest fault. See chapter
Fault code of the 3rd latest fault. See chapter
Status of digital inputs DI1...5 at the time the latest fault occurred. Example: 10000 = DI1
is on, DI2...DI5 are off.