SmartLogger2000
User Manual
Power Adjustment Parameters
Table 7-9 Parameter description
No.
Parameter
1
Active power
change
gradient
2
Fixed active
power derated
3
Active power
percentage
derating
4
Reactive
power change
gradient
Issue 04 (2018-04-10)
Description
Adjusts the change speed
of the inverter active
power.
Adjusts the active power
output of the inverter in
fixed values.
Adjusts the active power
output of the inverter in
percentages.
Adjusts the change speed
of the inverter reactive
power.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Unit
Value Range
%/s
1000 V inverter:
[0.1, 50]
Others: [0.1,
1000]
kW
1000 V inverter:
[0, Pmax]
Others: [0,
Pmax_limit]
%
[0, 100]
%/s
[0.1, 1000]
7 WebUI
Remarks
N/A
Pmax represents
the maximum
active power.
For 1000 V
inverters, the
maximum value
of this parameter
for the
SUN2000-25KTL
-US is 27.5 kW.
This parameter is
for the
SUN2000-100KT
L-USH0 only and
displayed when
Remote power
schedule is set to
Enable.
If this parameter
is set to 100, the
inverter delivers
the maximum
output power.
This parameter is
for the
SUN2000-100KT
L-USH0 only and
displayed when
Remote power
schedule is set to
Enable.
N/A
119