Huawei 5288 V3 V100R003 User Manual page 61

Table of Contents

Advertisement

5288 V3 Server
User Guide
Item
Acoustic noise
Corrosive air
pollutant
Particulate
pollutant
Power
consumption
Issue 26 (2018-11-19)
Specifications
The data listed in the following is the declared A-weighted sound
power levels (LWAd) and declared average bystander position A-
weighted sound pressure levels (LpAm) when the server is operating
in a 23°C (73.4°F) ambient environment. Noise emissions are
measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
l Idle:
– LWAd: 48.2 Bels
– LpAm: 65.5 dBA
l Operating:
– LWAd: 53.0 Bels
– LpAm: 70.3 dBA
NOTE
The actual sound levels generated when the server is operating vary depending
on the server configuration, workload, and ambient temperature.
l Corrosion rate of the copper test piece: < 300 Å/month (in
compliance with the ANSI/ISA-71.04-2013 gaseous corrosion
level G1)
l Corrosion rate of the silver test piece: < 200 Å/month
l The ISO14664-1 Class 8 requirements are met.
You are advised to ask a professional organization to monitor
particulate pollutants in the equipment room.
l There is no explosive, conductive, magnetic, or corrosive dust in
the equipment room.
The power consumption changes depending on the server
configuration. For details, see
Copyright © Huawei Technologies Co., Ltd.
2 Product Overview
Huawei Server Power
Calculator.
51