4.
With DIP switch No. 5, select the setting method of the remote
mode.
DIP switch No. 5
ON
OFF(initial setting)
Reference
• When DIP switch No. 5 is ON, the remote switch on the controller is not available.
5.
When DIP switch No. 5 is OFF, select the remote mode state at
powered ON with DIP switch No. 6.
DIP switch No. 6
ON
OFF (initial setting)
Reference
• When DIP switch No. 5 is ON, keep DIP switch No. 6 OFF.
• When DIP switch No. 6 is ON, "X5: REMOTE IN" signal on I/O terminal is not available.
CAUTION
6.
Install the DIP switch cover to the controller.
Notice
• A plastic cover is installed on the DIP switch. Install this cover always to avoid the dust penetration to the controller.
7.
Turn ON the power of laser marker.
20
Setting method of remote mode
Use the input signal of REMOTE IN (A3) on I/O terminal.
Use the remote switch on the front of the controller.
Remote mode state at powered ON
Starts up with remote mode ON
Starts up with remote mode OFF
• If the DIP switch No. 5 or No. 6 are used while turned on, construct a system
for re-pumping the laser manually as safety protection measures after the stop
of the laser radiation due to an emergency stop or an interlock.