Lp-4X0 "-055.000"-"+055.000" Lp-4X5/Lp-V15; Model Type* Setting Range [Mm] Lp-V10; Lp-4X0 Lp-4X5/Lp-V15; Lp-V10 "-045.000"-"+045.000 - Panasonic LP-400 Series External Control Manual

Laser marker
Hide thumbs Also See for LP-400 Series:
Table of Contents

Advertisement

⿎ Processing condition : LAY
Sets X/Y coordinate offset and laser power correction ratio, etc. for the specified processing condition No.
• Setting / Readout data of processing condition
Sub
STX
LAY
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of processing condition
STX
LAY
R
Data length

Name

[byte]
Processing
condition No.
Area No.
X offset
Y offset
Rotation angle
Laser power
correction
Scan speed
correction
(Laser pulse cycle
correction)
(Only for LP-V
series)
* For the detail of the model type, refer to "Target laser marker" (P.8).
[Processing condition No.] [Area No.] [X offset]
[Y offset] [Rotation angle] [Laser power correction]
[Scan speed correction]
[Laser pulse cycle correction]
Max. 34-byte (LP-V series),
Max. 31-byte (LP-400/LP-W series)

[Processing condition No.]

1-byte

Description

1
"0"–"7"
1
"0"–"9", "A"–"F"
Model type*
8
LP-V10
LP-4x0
LP-4x5/LP-V15
8
LP-4x1/LP-W
7
"-180.00"–"+180.00" [°]
3
"000"–"200" [%]
3
"005"–"500" [%]
(3)
"050"–"200" [%]
(Check
Delimiter
sum)
Setting range [mm]
"-045.000"–"+045.000"
"-055.000"–"+055.000"
"-080.000"–"+080.000"
"-027.500"–"+027.500"
ME-LP400V-EX-6
(Check
Delimiter
sum)
Remarks
Specifies which area part is the
marking position of the concatenated
marking on the flying object.
In case of marking static object,
specify "0".
• The correction ratio is calculated
using the value set at the laser
setting as 100%.
• With LP-400/LP-W series, nothing
should be input in Laser Pulse
Cycle Correction.
117

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents