1-3-3 Shift to remote mode

To control the laser marker externally using I/O or serial communication commands, set the operation mode to the remote
mode in one of the following methods.
Select the method to switch to the remote mode by setting the DIP switch on the rear side of the controller.
Use the remote switch on the front of the controller.
Turn ON the remote mode switch on the front of the controller.
Use input signal of X5 "REMOTE IN" on I/O terminal.
Turn ON the REMOTE IN (A3) of the I/O terminal on the rear of the controller.
Reference
• When DIP switch No. 5 is ON, the remote switch on the controller is not available.
Start the laser marker in the remote mode.
The laser marker starts up always in the remote mode state. Use the remote mode switch button of the controller for
releasing and resetting the remote mode.
OFF
ON
Reference
• When DIP switch No. 6 is ON, "X5: REMOTE IN" signal on I/O terminal is not available.
• The remote switch on the controller is available when DIP switch No. 6 is ON.
A3: REMOTE IN
ME-LP400V-EX-6
Check that DIP switch No. 5 is OFF.
Refer to "1-3-1 DIP switch setting" (P.19).
Check that DIP switch No. 5 is ON.
Refer to "1-3-1 DIP switch setting" (P.19).
Check that DIP switch No. 5 is OFF, and No. 6 is ON.
Refer to "1-3-1 DIP switch setting" (P.19).