⿎ Bar code marking data (ASCII code specified) : BCS
Sets character string to be encoded as a bar code or 2D code by ASCII code. For alphanumeric and symbols only.
• Setting / Readout data of marking character string
Sub
STX
BCS
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of bar code setting (one-byte character)
STX
BCS
R
Name
Bar code No.
Line No.
Bar code data
Reference
• When setting bar code marking data in multiple lines, data in each line are jointed in the order of line numbers and they
are coded as the data in one line. (No line break is inserted for each line.)
• When setting bar code marking data in multiple lines, the total input data should be 255 characters or less.
• If readout data includes function characters (such as "%SFT:0"), the setting character ("%SFT:0") is read out, but
characters to be actually marked are not.
• If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (Shift-JIS Code
Specified), only these 2-byte characters are read out in shift-JIS code. In this case, the maximum readout data will be
33-byte or more.
• Use the BBS command or BRS command when bar code data includes a control code.
• In the case that "GS1 Data Matrix" is selected as bar code type in bar code condition setting, the separator of variable
length AI data is inputted at GS (1D(HEX)) in this command. The separator can be coded as "FNC1" or "GS". Set
beforehand either "GS" or "FNC1" as the separator in Environment 3 on the environment setting screen.
• For CODE128 (GS1-128), GS1 DataBar Expanded, and 2D side of composite codes, the separator of variable length AI
data "FNC1" can be input by using 1D(HEX).
94
[Bar code No.] [Line No.]
[Bar code data]
Max. 33-byte
[Bar code No.] [Line No.]
Max. 3-byte
Data length
[byte]
1
"0"–"7"
1D code: "1"–"2"
1 or 2
2D code: "1"–"9"
2D part of Composite code: "01"–"09"
ASCII code characters within the range
from 20(HEX) to 7E(HEX).
Max. 30
(Functional characters should not be
included.)
FNC1 can be entered at 1D(HEX).
(Check sum)
(Check sum)
Delimiter
Description
ME-LP400V-EX-6
Delimiter
Remarks
Specifies the line for data setting.
Specifies the character setting in the
specified line.
Specify the data length with 0 byte in
order to delete the character string.