⿎ Lot condition : LTC
Sets the condition of "Lot Function" to change characters depending on date/time and counter values.
• Setting / Readout data of lot condition
Sub
STX
LTC
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of lot condition
STX
LTC
R
Name
Data length [byte]
Lot No.
Lot target
Period unit
Reference
• When the period unit of the lot condition (LTC command) is changed, the lot period and lot character (LTS command)
settings registered to that lot number are deleted.
92
[Lot No.] [Lot target] [Period unit]
4-byte
[Lot No.]
1-byte
Description
1
"0"–"7"
"00": current
2
"01"–"08": expiry 1 to 8
"10"–"17": counter 0 to 7
"0": year or counter
"1": month
"2": day
"3": Y/M
"4": M/D
1
"5": day of week
"6": hour
"7": week
"8": minute
"9": hour/min.
"A": week-based year
ME-LP400V-EX-6
(Check sum)
(Check sum)
Delimiter
"4"–"7": common lot
The unit of period to switch the character
string for marking is indicated.