⿎ RS-232C communication conditions
Item
Synchro system
Communication
Baud rate
Data length
Parity
Stop bits
Flow control
Check sum
Delimiter
Start code
Reception timer
Reference
• For the details of the setting method of communication conditions, refer to "1-3-2 Communication condition setting" (P.21).
RS-232C communication conditions
Start-stop method
Full-duplex transmission
1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps (initial setting: 9600 bps)
8-bit fixed
None / Even / Odd (initial setting: None)
1-bit / 2-bit (initial setting: 1-bit)
None
OFF / ON (initial setting: OFF)
CR / CR + LF (initial setting: CR)
• Setting request, Reading request, Reading response: STX
• Normal response: ACK
• Abnormal response: NAK
Timeout monitoring ON (10 sec.)