⿎ Counter reset : CTR
Resets the current counter value to the initial value.
• Counter reset
STX
CTR
S
Data length
Name
[byte]
Counter 0
Counter 1
Counter 2
Counter 3
Counter 4
Counter 5
Counter 6
Counter 7
⿎ Expiry date/time condition : LMT
Sets the expiry date/time condition.
Expiry date/time can be set within the range from January 1, 1980 to December 31, 2099.
• Setting / Readout data of expiry date/time condition
Sub
STX
LMT
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of expiry date/time Condition
STX
LMT
R
Name
Data length [byte]
Expiry No.
Expiry
Reference unit
Start date
[Counter 0 to 7]
8-byte
Description
1
1
1
1
"0": reset OFF
"1": reset ON
1
1
1
1
[Expiry No.] [Expiry]
[Reference unit] [Start date]
7-byte
[Expiry No.]
1-byte
Description
1
"1"–"8"
4
"-999"–"+999"
"0": year
"1": month
1
"2": day
"3": hour
"4": minute
"0": Today not included
1
"1": Today included
(Check sum)
Delimiter
Counter 4 to counter 7 are common counters.
(Check sum)
(Check sum)
Delimiter
"5"–"8": common expiry date/time
Possible to be set only when the reference
unit is set to "year" or "month". Indicating if
the date of "today" is included or not.
ME-LP400V-EX-6
Remarks
Delimiter
Remarks
91