1-1-13.
COMPOSITE COLOR LEVEL ADJ.
BOARD
F3 V IN
SPEC.
V 400mV ± 20mV
TEST POINT
TP503
ADJ.
VR451
compositeColor Ba
INPUT
75%
MODE
ASSEMBLE
TAPE
M.EQ
Oscilloscope
Adjust VR451 so that the C level is 400mV ±
1.
20mV.
Setup 7.5%
1-1-14. COMPOSITE COLOR DEMODULATION
TIMING ADJ.
BOARD
F3 V IN
SPEC.
TEST POINT
TP501
ADJ.
VR501,VR512
INPUT
Composite Color Bar
75%
MODE
ASSEMBLE
TAPE
M.EQ
Oscilloscope
1.
Turn VR512 fully CCW.
2.
Adjust VR501 so that the noise portion is
positioned on the top of A portion as shown in
figure.
3.
Adjust VR512 so that the V level at A portion is
0V.
Setup 7.5%