4-3-3. Burst Sample Phase Adj.(525)
Board
V_OUT (F6)
Specification
Test Point
TP8 (A-4), TP10 (B-4)
Adjustment
S/H PLS P, VR6 (A-3)
Point
Input Signal
REF IN = BB (NTSC)
Mode
EE, INT SG
Tape
M.EQ
Oscilloscope
1.
Place the unit in the 525 mode.
2.
Adjust VR6 so that the sample pulse is located at
center of the burst signal as shown in figure.
TP10
TP8
4-3-4. Burst Sample Phase Adj. (625)
Board
V_OUT (F6)
Specification
Test Point
TP8 (A-4), TP10 (B-4)
Adjustment
S/H PLS P, VR12 (A-4)
Point
Input Signal
REF IN = BB (PAL)
Mode
EE, INT SG
Tape
M.EQ
Oscilloscope
1. Place the unit in the 625 mode.
2. Adjust VR12 so that the sample pulse is located at
center of the burst signal as shown in figure.
TP10
TP8