Cleaner Solenoid Replacement
3-7-22.
Cleaner
Adjustment
Tool
Eccentric Driver (VFK0357)
1.
Push the Cleaner Solenoid Shaft and confirm the
clearance between Cleaning Arm Unit and Cleaner
Base Plate (D) is 0.5 mm to 0.7 mm.
2.
If it is out of specification, loosen 2 screws (A) and
move the cleaner solenoid arrow C direction and
adjust the clearance (D) is in the specification.
3.
Push the cleaner solenoid shaft and confirm that the
cleaner roller touches the cylinder. Then confirm
that the cleaner roller returns original position when
the shaft is released.
4.
Push the Solenoid shaft and rotate the cylinder and
confirm that the cleaner roller is rotated by the
cylinder movement.
Solenoid
Position
Cleaner Solenoid Position Adjustment
Cleaner Solenoid Position Adjustment
Note: If the Cleaner Base Plate is moved, Cleaner
Roller Position Adjustment is necessary.