4-6-27.Error Rate Confirmation (50M)
Board
RF EQ
Specification
Test Point
Adjustment
Service Menu
Point
Input Signal
Mode
PLAY
Tape
VFM3580KM (Color Bar Portion)
M.EQ
1.
Set the items in the USER MENU as follows.
012 SYS FORMAT :
013 PB FORMAT
2.
Open the Service Menu and select item B00 EQ
ED ADJUST Menu.
3.
Playback a 25M Master Tape.
4.
Set the item as follows.
B43 ERROR MODE :
5.
Measure each error rate about L1, L2, R1, R2.
(VIDEO/AUDIO)
6.
Confirm that the error rate is displayed less than
6 segments on the error meter.
Front TC SW
INT
EXT
7.
Set the item as follows.
B42 PB MODE :
8.
Measure each error rate about L1, L2, R1, R2.
(VIDEO/AUDIO)
9.
Confirm that the error rate is less than 14
segments on the error meter.
10. Eject the 25M Master Tape and playback a 50M
color bar Tape.
11. Confirm that the color bar is displayed on the
monitor.
422
:
MANUAL
SLOW
Measurement Mode
VIDEO Error
AUDIO Error
RP H
4-6-28. Error Rate Confirmation (25M)
Board
RF EQ
Specification
Test Point
Adjustment
Service Menu
Point
Input Signal
Mode
PLAY
Tape
VFM3580KM (Color Bar Portion)
M.EQ
1.
Set the items in the USER MENU as follows.
012 SYS FORMAT :
013 PB FORMAT
2.
Open the Service Menu and select item D00 EQ
DP ADJUST Menu
3.
Playback a 25M Master Tape.
4.
Set the item as follows.
D43 ERROR MODE :
5.
Measure each error rate about L1, L2, R1, R2.
(VIDEO/AUDIO)
6.
Confirm that the error rate is displayed less than
6 segments on the error meter.
Front TC SW
INT
EXT
7.
Set the item as follows.
B42 PB MODE :
8.
Measure each error rate about L1, L2, R1, R2.
(VIDEO/AUDIO)
9.
Confirm that the error rate is less than 14
segments on the error meter.
411
:
MANUAL
SLOW
Measurement Mode
VIDEO Error
AUDIO Error
RP H