4-3-7. CF PHASE ADJUSTMENT (1)(625)
Board
V_OUT (F6)
Specification
Test Point
TP4 (A-2), TP7 (B-4)
Adjustment
CF ADJ P, VR13 (A-3)
Point
Input Signal
REF IN = BB (PAL)
Mode
EE, INT SG
Tape
M.EQ
Oscilloscope
1.
Place the unit in the 625 mode.
2.
Scope : CH1 SG CF
CH2 TP4
TRIG. SG CF falling edge.
3.
Rotate the VR13 fully to CCW.
4.
Rotate the VR13 to CW.slowly
5.
Set the VR13 so that the waveform phases are
same as shown in figure
SG CF
TP4
NG
The CF waveform is different by SG type.
4-3-8. CF PHASE ADJUSTMENT (2)(625)
Board
V_OUT (F6)
Specification
Test Point
TP1 (B-1), TP2 (B-1)
Adjustment
CF ADJ P, VR13 (A-3)
Point
Input Signal
REF IN = BB (PAL)
Mode
EE, INT SG
Tape
M.EQ
Oscilloscope
1.
Place the unit in the 625 mode.
2.
Adjust VR13 so that the pulse (TP2) is at center of
the High period of TP1
3.
After adjustment, confirm that CF phase (refer to
the item CF PHASE ADJUSTMENT(1) (625) )
Trigger
TP1
TP2
B
A