4.0 ± 0.5dB
TRACE B
TRACE A
5M
9.
Add "+110" to the value of C01 REC CURR L1
and C03 REC CURR L2.
(Ex. In case of -50 → +60)
10. After adjustment, compare the spectrum of
Master Playback and Confidence Playback.
3.0 ± 0.5dB
20M
4-6-31. Comparison Of the Spectrum of
Master PB and Confidence PB (50M Lch)
Board
RF EQ
Specification
Test Point
TP104, TG101, TP2, TG1
Adjustment
Point
Input Signal
INT SIG color bar
Mode
REC, PLAY
Tape
RP/PB Tape, VFM3580KM
M.EQ
Spectrum Analyzer
1.
Place the unit in the REC mode.
2.
Store the Confidence Playback spectrum in
TRACE-B.
3.
Playback a 25M Master Tape
4.
Store the Master Playback spectrum in TRACE-A.
5.
Confirm the level at 5MHz is as follows.
TRACE-A Level - TRACE-B Level = ± 2.0 dB