USER menu
<VIDEO>
No.
600
601
602
603
604
605
606
607
608
609
610
611
<Note>
612
When no optional board
(AJ-YA951) has been
installed, setup menus
No. 610 through No. 612
are not displayed.
The underline on the setting item denotes the initial setting.
Item
Setting
Superimposed
Superimposed
No.
display
display
INT SG
0000
0001
0002
OUT
0000
VSYNC
0001
V-MUTE
0000
SEL
0001
CC (F1)
0000
BLANK
0001
CC (F2)
0000
BLANK
0001
FREEZE
0000
SEL
0001
OUT C
0000
KILL
0001
V OUT
0000
SETUP
0001
SDI OUT
0000
COMPNT
SEL
0001
COMPST
EDH
0000
0001
P
/P
0000
B
R
IN LV
0001
INPUT
0000
C KILL
0001
IN FRM
0000
FORCED
DET
0001
– E-57 –
OFF
This selects whether to generate the internal signal.
0: Signal is not generated.
BB
1: The black burst is generated.
CB
2: 100% colour bars are generated.
N-VF
This selects whether to float the vertical sync position of the
video output in order to align the video output phase with the
VF
input in the EE/record/edit modes.
0: Signals are not floated.
1: Signals are floated.
N-MUTE
This selects whether the video output signal is set to MUTE
when LOW RF is detected during playback.
LOW RF
0: No muting. (Freeze)
1: Muting. (Set to gray.)
BLANK
This selects ON or OFF for the closed caption signal in the
first field.
THRU
0: Forced blanking performed.
1: Blanking not performed.
This selects ON or OFF for the closed caption signal in the
BLANK
second field.
THRU
0: Forced blanking performed.
1: Blanking not performed.
This selects the freeze mode for still pictures.
FIELD
0: Field freeze.
FRAME
1: Frame freeze.
<Note>
When frame freeze has been selected, the frame slow status
is established with the slow setting.
This selects chroma colour killer processing for the video
B/W
output signals.
COLOR
0: The signals are forcibly processed as B/W signals.
1: The signals are automatically processed.
This selects the composite output signal.
THRU
0: The signal is output without setup.
ADD
1: The signal is output with 7.5% setup.
<Note>
This setup menu is not displayed in the 625 mode.
This selects the SERIAL OUT signal format.
0: The component 4:2:2 signal is output.
1: The composite signal is output. (option)
OFF
This selects whether to superimpose EDH onto the serial
output signals.
ON
0: EDH is not superimposed.
1: EDH is superimposed.
M
II
This selects the component input signal level.
0: M
II
level.
B-CAM
1: ß cam level.
B/W
This selects colour killer processing for the video input signals.
0: The signals are forcibly processed as B/W signals.
AUTO
1: The signals are automatically processed.
This selects the conditions under which frame detection is to
be performed when signals are input.
AUTO
0: Frame detection is performed at all times.
1: Frame detection is prohibited only when non-standard
signals are input.