minimum.
3. Adjust B09 PB PLL SL R so that the R1 and R2 error rate is
minimum.
4. Confirm the error rate on the error meter.
5. When the segment is displayed in more than 7 segments on the
error meter, adjust the following items.
B04 PB GAIN L1 , B05 PB PHASE L1
B06 PB GAIN L2 , B07 PB PHASE L2
B11 PB GAIN R1 , B12 PB PHASE R1
B13 PB GAIN R2 , B14 PB PHASE R2
6.6.16. EQ Adjustment (50M RP Lch)
Board
Specification
Test Point
Adjustment Point
Input Signal
Mode
Tape
M.EQ
1. Playback the 25M Master Tape.
2. Set the item as follows
B42 PB MODE : RP H
3. Adjust B15 RP PLL PHS L and B16 RP PLL SL L so that the L1 and
L2 error rate is minimum.
4. Adjust B30 RP MAIN DL L so that the L1 and L2 error rate is
minimum.
5. Adjust B17 RP AEQ L so that the L1 and L2 error rate is minimum.
6. Adjust B18 RP GAIN L1 and B19 RP PHASE L1 so that the L1 error
rate is minimum.
7. Adjust B20 RP GAIN L2 and B21 RP PHASE L2 so that the L2 error
rate is minimum.
8. Adjust B15 RP PLL PHS L and B16 RP PLL SL L so that the L1 and
L2 error rate is minimum
6.6.17. EQ Adjustment (50M RP Rch)
RF EQ
Error Meter
Service Menu
Playback
VFM3580KM (Color Bar
Portion)