Panasonic DVC PRO Studio AJ-D950P Service Manual page 38

Vtr/analog video interface kit
Table of Contents

Advertisement

Specification
Test Point
Mode
Tape
M. EQ.
1. Place the VTR in REV, REW, FF and confirm that the Waveform is
the same diamond style.
2. Peak level V is always in the following specification. V/Vmax >= 0.9
3. If it is not confirm the S4 Post Height.
5.6.26. Envelope Confirmation
Test Point
Mode
Tape
M. EQ.
This Adjustment must be done after " Envelope waveform Adjustment".
Refer to Figure
TP201 ENV (RFEQ:H3)
REV, REW, FF
VFM3580KM (No.1)
Oscilloscope
TP201 ENV (RFEQ:H3)
REW/REV to PLAY
Loading completion to PLAY
FF to PLAY
L cassette (123 min pre-recorded)
Tape begin
Oscilloscope
38

Advertisement

Table of Contents
loading

Table of Contents