5.7.24. M Stopper Solenoid Replacement and Adjustment
(Removal of M Stopper Solenoid)
1. Remove the top panel.
2. Remove the front loading unit.
3. Remove the connector P24 on the Mech. Interconnection board.
4. Remove 4 screws (A) and (B) and remove the M Stopper Solenoid.
(Installation of M Stopper Solenoid)
1. Install a new M Stopper Solenoid as reverse order of its removal.
2. After its installation following adjustment is necessary.
(Adjustment Procedures)
1. Set the Reel Table at L cassette position.
2. Release the M Stopper by pushing the M Stopper Solenoid Shaft.
3. Loosen the screw (A) and adjust the M Stopper Solenoid Unit
Position so that the Gap (A) between Mech. Chassis and M Stopper
is 1.1 mm to 1.3 mm.
Cleaner Roller Position Adjustment