3-7-23. Cleaner Roller Position Adjustment
Tool
Eccentric Driver (VFK0357)
1.
Confirm that the clearance (A) between cylinder unit
and cleaner roller is 1.0 mm to 1.2 mm.
2.
If it is out of specification loosen screw (B) and move
the cleaner base unit and adjust its position by the
eccentric driver.
Cleaner Roller Position Adjustment
3-7-24. M Stopper Solenoid Replacement
and Adjustment
(Removal of M Stopper Solenoid)
1.
Remove the top panel.
2.
Remove the front loading unit.
3.
Remove the connector P24 on the Mech.
Interconnection board.
4.
Remove 4 screws (A) and (B) and remove the M
Stopper Solenoid.
(Installation of M Stopper Solenoid)
1.
Install a new M Stopper Solenoid as reverse order
of its removal.
2.
After its installation following adjustment is
necessary.
M Stopper Solenoid Removal
(Adjustment Procedures)
1.
Set the Reel Table at L cassette position.
2.
Release the M Stopper by pushing the M Stopper
Solenoid Shaft.
3.
Loosen the screw (A) and adjust the M Stopper
Solenoid Unit Position so that the Gap (A) between
Mech. Chassis and M Stopper is 1.1 mm to 1.3 mm.
M Stopper Solenoid Position Adjustment