3-7-8. Supply and Take-up Brake Arm Unit
Replacement
(Removal of Brake Arm Unit)
1.
Remove the top panel.
2.
Remove the front loading unit.
3.
Push the supply and take-up brake solenoids to
release brake.
4.
Remove 2 cut washers (A) and remove supply
and take-up brake arm unit.
(Installation of Brake Arm Unit)
1.
Install new supply and take-up brake arm units as
reverse order of removal.
Note:
Hook the brake arm spring at the position
shown in the figure.
2.
After the Brake Arm Unit Installation, confirm the
Main Brake Torque. (Refer to the Main Brake
Torque Confirmation.)
Reel Brake Arm Unit Replacement
3-7-9. Supply Brake Solenoid Replacement
and Adjustment
(Removal of Supply Brake Solenoid)
1.
Remove the top panel.
2.
Remove the front loading unit.
3.
Remove the bottom panel.
4.
Remove
the
connector
Interconnection board.
5.
Remove 2 screws (A) and remove the Supply
Brake Solenoid Base Unit.
6.
Remove 2 screws (B) and remove the Supply
Brake Solenoid from its unit.
Supply Brake Solenoid Removal
(Installation of Brake Solenoid)
1.
Install a new supply brake solenoid as reverse
order of its removal.
Note:
Set the supply brake spring at the
position shown in the figure.
2.
After installation, adjust following procedures.
P15