3. Read the Dial Tension Meter when the voltage is 3.8 V (PLAY
position) at TP201, and adjust the Tension Regulator Spring Hook
(B)
4. To adjust the Tension Regulator Spring Hook (B) position, loosen
the Tension Regulator Spring position and after adjustment tighten
the screw C
5.6.10. REV Tension Confirmation
Board
Specification
Test Point
Mode
M. EQ.
1. Place the VTR into no tape loading.
2. Press the tension post by the Dial Tension Meter to R direction in
STOP mode.
3. Read the Dial Tension Meter when the voltage is 1.2 V (REV
position) at TP201, and adjust the Tension Regulator Adjustment
again.
4. Grew the screw A, B and C after Tension Arm adjustment. The
grew quantity at B is half of A and C.
SERVO
18+/-2gf
TP201
STOP
Digital Volt meter
VFK1188(30g Dial Tension Gauge)