3. If it is not, adjust VR2 (Mech. I/F) so that the voltage is in the
Specification.
4. Then set VFK1155.
5. Set the VTR in no tape loading mode and confirm the voltage at
TP201 is in the specification in STOP mode. If it is not, adjust
"Tension Arm Neutral Position Adjustment" again. If is out of
specification after this adjustment, replace the tension post unit.
5.6.9. Tension Regulator Spring Adjustment
Board
Specification
Test Point
Adjustment
Mode
M. EQ.
1. Set the VTR in no tape loading.
2. Press the tension post by the Dial Tension Meter to R direction in
STOP mode.
SERVO
11+/-1gf
TP201(SERVO:F1)
Tension Regulator Spring Hook (B)
STOP
Digital Volt Meter.
VFK1188(30g Dial Tension Meter)