Panasonic DVC PRO Studio AJ-D950P Service Manual page 68

Vtr/analog video interface kit
Table of Contents

Advertisement

5.7.17. Replacement of Tension Arm Unit
(Removal of Tension Arm Unit)
1. Remove the top panel.
2. Remove the front loading unit.
3. Remove the cut washer (A) and remove the tension regulator
spring from its hook then remove the tension arm unit.
(Installation of Tension Arm Unit)
1. Install the new Tension Arm Unit as reverse order of its removal.
2. After installation adjust tension arm adjustment following the
tension arm adjustment flow chart.
Removal of S5 Post Base Unit
Removal of Tension Arm Unit
68